Detector Kit 25 KV G2 AC
SNCF approval N°: In progress
ref: VAT25KVG2
Description of use
Checking the absence of voltage on 25 KV power lines (alternating power) before Maintenance activities.
Added value
- Instant result shown by green LED's lights and powerful sound.
- P-FIX connection (4NRJ patent) for a quick and simple setting with SNCF pole.
- Antenna with two-layer fiberglass (wear indicator) with central electrode.
- Tamper-proof and waterproof electronic compartment for direct access to the battery.
- PIVAT pole quickly unfolded.
- QR code traceability solution for a better customer follow-up regarding certification, user manual, conformity dates and periodic controls.
Technical features
- Unipolar voltage measurement (electric field measurement)
- Tool equipped with a self-test
- Permanent threshold control
- Voltage range: 25 KV AC or 2 x 25 KV AC
- Operating temperatures: -25 °C to +55 °C
- Detection threshold: 6900V
- Dimensions: 460 x 154 x1545 mm
- Weight: 1.47kg
- Complies with standard: IEC 61243-1
Description kit
- Voltage absence tester (VAT25KVG2)
- Pentagonal pole (PIVAT)
- Silicone cloth (CHISIL)
- 1 spare 9V battery (6LR61)
- Carrying case (SACVAT25KVG2)
Product sheet